productphoto
productphoto
productphoto
productphoto

Part: 6051.2037

Free Sample Request

VAC13KS, Interconnection, V-Lock cord retaining, 0.6 m, Connector IEC C13, H05VV-F3G0.75, black


Connectors (Inlets/Outlets)

C13
Connector Logo
70° C
E
Connector Logo
70° C

Approvals and Compliances

Description 6051.2037

Description

  • Interconnection Cord,
  • Protection class I, Pin temperature 70 °C,
  • with V-Lock interlocking system

Approvals

  • Approval Reference Type: VAC13KS
Date Category Subcategory Title Download
13/06/2016 Products
PCS
US cordset 10A 2.0m, V-Lock PCS
09/11/2010 Products
White Paper
White Paper Mating Connectors English
24/11/2017 Products
Connectors
White Paper Mating Connectors
24/03/2017 Products
White Paper
White Paper Cord retention

Ratings IEC

The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses

Ratings IEC, UL/CSA
General information on the rated current and the rated voltage at EMC products

Rated Voltage
Rated current
The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families


Approvals

10 A / 250 VAC; 50 Hz

Dielectric Strength

Information abou the maximum permissible voltage, to avoid a voltage breakdown due to insulation damage.


Dielectric Strength

> 2 kVDC between L-N
> 2 kVAC between L/N-PE
(1 min/50 Hz)

Allowable Operation Temperature

-25 °C to 70 °C

IP-Protection

The IP code consists of a two-digit number, which indicates the respective degree of protection.

The first digit specifies the protection from the penetration of foreign objects, the second digit the protection from water penetration with harmful effects.

Details about IP protection degree can be looked up in the general product information

IP-Protection

from front side IP 20 acc. to IEC 60529

Insulation cover

Class I: with ground; Class II: without ground

Detailed information relating to protection class can also be found in the general product information


Insulation cover

Suitable for appliances with protection class I acc. to IEC 61140

Terminal

Terminals according IEC Standard.

Detailed information about terminals can be looked up in the date sheet or in the general product information.

Terminal

moulded

Material: Housing

PVC, black

appliance inlet/-outlet

Connector type according to IEC 60320-1 resp. IEC 60320-2-2, UL498, CSA C22.2 no.42

Details on connectors and their names can be found in the general product information

Appliance Couplers
Mating Connectors
Term explanation
Special Connector Designs

C13 acc. to IEC 60320-1
(for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I


Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  
General Product Information

Preview
 

Picture(s) Selection of product pictures to display a specific variant of the type

Type
 

Type Corresponds to a product series and includes various distinct variants. On the type of descriptive data are summarized, eg in the data sheet

Order Number
 

Order Number Unique part number for placing an order

Configuration key
 

Configuration key The configuration key of a product consists of the composite key values, which describe the different kinds of attribut distinction.

Comment
 
Model Description
 

Model Description Abbreviated description of the CAD model

IGS
 

IGS Also mentioned as IGES ( Initial Graphics Exchange Specification). Common program indipendent interchange format for 3D CAD data.

Step
 

Step Also mentioned as STEP ( Standard for the Exchange of Product Model Data). Common program indipendent interchange format for 3D CAD data standardized according ISO standard.

Parasolid
 

Parasolid Parasolid modeling kernel is a 3D CAD systems. It is developed by a separate business unit within the Unigraphics Solutions (UGS), now Siemens PLM Software.

DXF
 

DXF (Drawing Interchange Format) is a specified by the Autodesk file format for CAD data exchange, and was developed for the 2D-CAD program AutoCAD. A DXF file describes a CAD model as plain text to the ASCII standard.

Short Table of Variants 6051.2037


Connector cable Order Number

The link on the respective order number refers to a separat tab with specific detailed information .

This assures better readable information of the selected product.
Change to the tab All Products in order to show details of another variant.

This approach offers to use generic alias link to the product details:

www.schurter.xx/art/ [Order Number]

where the following variables are used:
- xx is the country specific domain
- [Order Number]

A=Most Popular

Most popular products have the following customer benefits:

- previously ordered by multiple customers
- generally in stock for immediate delivery
- early adoption or mature life cycle

Contact us for availability on other product variants, lead-times vary:

Contact-Form
Availability for all products can be searched real-time. Enter part number and required quantity:

Stock Check SCHURTER

Free Sample

Please ask for free sample in order to check if the products meets your requirement for your application. Send your delivery adress and your specific requirements.

Distributor Stock Check

The following links reffers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.

The
Distributor Stock Check

Stock Check Distributor

...
Type   V-Lock   Cord Type   Conductor cross section   Length [m]   Color              
 
C13 H05VV-F3G0.75 3 x 0.75 mm² 0.6 black 6051.2037 ...

We recommend for new applications the type (1)

[Swipe to the left and right for more options]

Mating Outlets/Connectors (6)

[Swipe to the left and right for more options]

6600-3

IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal

6600-4

IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal

6600-5

IEC Appliance Outlet F, Integrated Light Pipes, PCB terminals, Color Coding

6602-4

6602-4, Mounting: Snap-in version, Appliance Outlet: IEC H, Solder terminals or quick connect terminals, 10 A, Suitable for appliances with protection class II

6610

IEC Appliance Outlet F, Snap-in Mounting, Front Side, IDC Terminal

6610-5

IEC Appliance Outlet F, Snap-in Mounting, Front Side, IDC Terminal, integrated Light Pipe, Color Coding

Mating Inlets/Plugs shuttered (39)

[Swipe to the left and right for more options]

6010

6010, Mounting: Snap-in, Solder, quick-connect, screw, PCB, Appliance Inlet: IEC C14

6015

6015, Mounting: Snap-in, Solder, quick-connect, screw, PCB, Appliance Inlet: IEC C18

6048

6048, Mounting: Screw, Appliance Inlet: IEC C14

6061

6061, Mounting: Screw, Appliance Inlet: IEC C14

GSP1

GSP1, Mounting: Screw, Appliance Inlet, IEC C14, For PCB mounting, IP 40, Quick connect terminals 4.8 x 0.8 mm angled or straight, Suitable for appliances with protection class I or II

GSP2

GSP2, Mounting: Sandwich, Appliance Inlet, IEC C14, For PCB mounting, IP 40, angled to pin axis, Suitable for appliances with protection class I or II

5120

5120, Mounting: Screw, Front-/Rear-Side, Filter: Standard and Medical Version, Without fuse holder: 10 A, Themoplast / steel tin-plated Appliance Inlet: IEC C14, Suitable for appliances with protection class I or II

5123

5123, Mounting: Screw, Front-/Rear-Side, Filter: Standard and Medical Version, Without fuse holder: 10 A, Themoplast / steel tin-plated Appliance Inlet: IEC C14, Suitable for appliances with protection class I or II

5150

5150, Mounting: Screw, Front-/Rear-Side, Filter: Standard, medical and industrial version, Without fuse holder: 10 A, Themoplast / steel tin-plated Appliance Inlet: IEC C14, Suitable for appliances with protection class I

KFS

KFS, Mounting: Screw, Front Side, Filter: Standard Version, Without fuse holder: 10 A, Appliance Inlet: IEC C14, prewired

DC11

DC11, Mounting: Screw, Rocker switch: non-illuminated or illuminated 1 or 2 pole, Quick connect terminals 4.8 x 0.8 mm, Appliance Inlet: IEC C14, Without fuse holder: Suitable for appliances with protection class I or II

DC21

DC21, Mounting: Screw Rear Side, Rocker switch: non-illuminated or illuminated 2-pole, Quick connect terminals 4.8 x 0.8 mm Appliance Inlet: IEC C14, Without fuse holder:

DD11

DD11, Mounting: Screw-on mounting, Rocker switch: non-illuminated or illuminated 2-pole, Quick connect terminals 4.8 x 0.8 mm, Appliance Inlet: IEC C14, With or without protection cover, Fuse holder: 1 or 2 pole, Suitable for appliances with protection class I

DD21

DD21, Mounting: Screw-on mounting Rear Side, Rocker switch: non-illuminated or illuminated 2-pole, additional quick connect 4.8 x 0.8 mm Appliance Inlet: IEC C14, Fuse holder: 1 or 2 pole

KD

KD, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, voltage selector: 2-4 digits, Fuse holder: 1 or 2 pole, Rocker switch, non-illuminated, 2-pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I

KG

KG, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, voltage selector: Fuse holder: 1 or 2 pole, Rocker switch, non-illuminated, 2-pole, Appliance Inlet: IEC C14, 250 VAC, partially wired, Suitable for appliances with protection class I

6135

6135, Mounting:Quick connect terminals 6.3 x 0.8 mm, Without fuse holder: 2-pole, Appliance Inlet: IEC C14, 250 VAC, unwired, Suitable for appliances with protection class I

DF11

DF11, Mounting: Screw, Rocker switch: non-illuminated or illuminated 2-pole, Quick connect terminals 6.3 x 0.8 mm, Appliance Inlet: IEC C14, Without fuse holder: Suitable for appliances with protection class I 0 DF11, Mounting:Screw, Quick connect terminals 6.3 x 0.8 mm, Without fuse holder: Rocker switch, non-illuminated or illuminated, 2-pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I 0 DF11, Power Entry ModuleC14, 55°C, version: L: N: ground: : fuseholder: color: design: dimension S: features: 0 DF11, Mounting: Snap-in or screw-on, Appliance Inlet: IEC C14, Without fuse holder: : black, Suitable for appliances with protection class I 0 DF11, Mounting: Snap-in or screw-on, 8 mm, Appliance Inlet: IEC C14, Circuit Breakers TA45: DF11, Suitable for appliances with protection class I 0 0

KP (Switch)

, Mounting: Screw, mm, : 2-pole, : IEC C14,

KP (FH)

KP (SiHa), Mounting: mm, Fuse holder: 1 or 2 pole, Appliance Inlet: IEC C14, Quick connect terminals 4.8 x 0.8 mm

GSF1

GSF1, Mounting: Fuse holder: optional, 1 or 2 pole, Appliance Inlet: IEC C14, Suitable for appliances with protection class I

GSF2

GSF2, Mounting: Snap-in, Appliance Inlet: IEC C14, Fuse holder: 1 or 2 pole, Solder terminals or quick connect terminals : black, Suitable for appliances with protection class I or II

KEA

KEA, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, voltage selector: 2-4 digits, Fuse holder: 1 or 2 pole, Appliance Inlet: IEC C14, 250 VAC, prewired or unwired, Suitable for appliances with protection class I

KEA-Print

KEA-Print, Mounting: Screw, Front-/Rear-Side, Fuse holder: 1 or 2 pole, Appliance Inlet: IEC C14, Suitable for appliances with protection class I

4707

4707, Mounting:Screw, Solder terminals or quick connect terminals, Fuse holder: 1 or 2 pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I or II

KEC

KEC, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, voltage selector: 2-4 digits, Fuse holder: 1 or 2 pole, Appliance Inlet: IEC C14, 250 VAC, prewired or unwired, Suitable for appliances with protection class I

KE

KE, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, voltage selector: Fuse holder: 1 or 2 pole, Appliance Inlet: IEC C14, 250 VAC, prewired or unwired, Suitable for appliances with protection class I

DC12

DC12, Mounting: Screw, Front-/Rear-Side, Filter, Standard and Medical Version, Without fuse holder:10 A, Rocker switch: 1 or 2 pole, non-illuminated or illuminated Appliance Inlet: IEC C14, prewired

DC22

DC22 Mounting: Screw, Rear Side, PCB, 10 A, Filter: Standard and Medical Version, Without fuse holder: Rocker switch: 1 or 2 pole, non-illuminated or illuminated, Appliance Inlet: IEC C14, Suitable for appliances with protection class I

DD12

DD12, Mounting: Screw-on mounting, Front Side, Filter, Standard and Medical Version, Fuse holder:1 or 2 pole, 10 A, Rocker switch: 2-pole, non-illuminated Appliance Inlet: IEC C14, prewired

DD22

DD22 Mounting: Screw-on mounting, Rear Side, PCB, 10 A, Filter: Standard and Medical Version, Fuse holder: 1 or 2 pole, Rocker switch: 2-pole, non-illuminated, Appliance Inlet: IEC C14, Suitable for appliances with protection class I

CD

CD, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Fuse holder: 1 or 2 pole, Front Side, 10 A, 2-pole, voltage selector: step, 2-4 digits, Appliance Inlet: IEC C14, prewired

CG

CG, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Fuse holder: 1 or 2 pole, Front Side, 10 A, 2-pole, voltage selector: series-parallel, Appliance Inlet: IEC C14, partially wired

DF12

DF12, Mounting : Screw, 8 mm, 15 A, prewired, Standard and Medical Version, Appliance Inlet: IEC C14 Circuit Breakers TA45: Suitable for appliances with protection class I

KFA

KFA, Mounting: Screw, Front-/Rear-Side, Filter: Standard and Medical Version, Fuse holder: 1 or 2 pole, Front Side, 10 A, voltage selector: step, 3 pos., Appliance Inlet: IEC C14, prewired

DA22

Mounting: Screw, from rear-side, A, Filter: Standard Version, Rocker switch: 2-pole, non-illuminated, : IEC C14, Suitable for appliances with protection class I or II

KFC

KFC, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Fuse holder: 1 or 2 pole, Front Side, 10 A, voltage selector: step, 3 pos., Appliance Inlet: IEC C14, prewired

CE

CE, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Fuse holder: 1 or 2 pole, Front Side, 10 A, voltage selector: series-parallel, Appliance Inlet: IEC C14, partially wired

5707

5707, Mounting: Screw, Front-/Rear-Side, Filter: Standard and Medical Version, Fuse holder: 1 or 2 pole, Front Side, 8 A, Appliance Inlet: IEC C14, Suitable for appliances with protection class I or II

Mating Outlets/Connectors shuttered (1)

[Swipe to the left and right for more options]

6600-5

IEC Appliance Outlet F, Integrated Light Pipes, PCB terminals, Color Coding