• Newsroom
  • Contact
  • safe&easy
  • DE EN 中文
results out of Read more Products View all results

Share

Share this page

You can share this page with others by sending the URL of the selected page.

Email LinkedIn
DD12 | Screw-on mounting horizontal (version B) Order required accessories separately
Screw-on mounting horizontal (version B)
Order required accessories separately
DD12 | Screw-on mounting vertical (version A)
Screw-on mounting vertical (version A)
DD12 | Snap-in mounting
Snap-in mounting
DD12 | Screw-on mounting horizontal (version B) Order required accessories separately
DD12 | Screw-on mounting vertical (version A)
DD12 | Snap-in mounting

Series: DD12

New_Logo Free Sample Request

IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole, Line Switch 2-pole

52 Variants


Connectors (Inlets/Outlets)

C14
Connector Logo
70° C

Description DD12

Description

  • Panel mount: Screw-on from front side
  • 4 Functions: Appliance Inlet Protection class I, Line Switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 1  or 2 pole, Line filter in standard and medical version
  • V-Lock notch standard
  • Quick connect terminals 6.3 x 0.8 mm

Unique Selling Proposition

  • Various mounting options
  • Attractive flat design
  • Switch for highest inrush current
  • V-Lock cord retaining

Characteristics

  • Ultra-compact design. Ideal for low profile designs
    Aluminum case provides good shielding
  • All single elements are already wired
  • Fuse drawer meets requirements of medical standard IEC/EN 60601-1
  • Ideal for application with high transient loads
  • Suitable for use in equipment according to IEC/UL 60950
    Suitable for use in medical equipment according to IEC/UL 60601-1

Other versions on request

  • Solder terminals
  • Fuse drawer 1-pole, plus spare fuse case
  • Fuse drawer 2-pole, with shorting bar
  • Other rocker marking
  • Line switch, illuminated
  • Line switch 1-pole
  • Medical version M80
  • Class X1- and Y1-capacitors for enhanced withstand voltage
Date Category Subcategory Language Title Download
09/08/2018
Products White Paper English White Paper Cord retention
09/08/2018
Products Flyers English Flyer V-Lock cord-retention safeguard
13/07/2018
Products PCN English All connectors PG06 PCN Change of configuration code PG06
04/07/2018
Products PCN English DD12 PCN Change of product packaging
06/04/2018
Products White Paper English White Paper Mating Connectors English
08/03/2018
Products Flyers English Flyer Components and Solutions for Medical Equipment
15/12/2017
Products White Paper English White Paper Components and IEC 60335-1
24/11/2017
Products White Paper English White Paper Components and IEC 60335-1
24/11/2017
Products White Paper English White Paper Leakage currents
24/11/2017
Products White Paper English White Paper Fuseholder standard
09/09/2017
Products White Paper English White Paper Power Consumption
17/11/2016
Products PCN English DD12 PCN
20/04/2016
Products PCS English DD12
20/04/2016
Products PCN English DD12

Ratings IEC

Ratings IEC


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses

Ratings IEC, UL/CSA
General information on the rated current and the rated voltage at EMC products

Rated Voltage
Rated current
The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families


Approvals

1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz

Ratings UL/CSA

Ratings UL


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses

Ratings IEC, UL/CSA
General information on the rated current and the rated voltage at EMC products

Rated Voltage
Rated current
The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families


Approvals

1 - 8 A @ Ta 40 °C / 250 VAC; 60 Hz

Leakage Current

Leakage Current


The leakage current is an electric current flowing in an undesirable current path. In EMC filters this is done by the applied Y-capacitors, which are used for noise suppression. Information on the amount and classification of leakage currents are explained in detail and are listed in the data sheets.

Leakage Current

standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)

Dielectric Strength

Dielectric Strength


Information abou the maximum permissible voltage, to avoid a voltage breakdown due to insulation damage.


Dielectric Strength

> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (1 min/50 Hz)

Allowable Operation Temperature

-25 °C to 85 °C

Climatic Category

Climatic Category


Disposition of components in categories for the assessment of mechanical and electrical properties.

Climatic Category

25/085/21 acc. to IEC 60068-1

IP-Protection

IP-Protection


The IP code consists of a two-digit number, which indicates the respective degree of protection.

The first digit specifies the protection from the penetration of foreign objects, the second digit the protection from water penetration with harmful effects.

Details about IP protection degree can be looked up in the general product information

IP-Protection

from front side IP 40 acc. to IEC 60529

Protection Class

Protection Class


Class I: with ground; Class II: without ground

Detailed information relating to protection class can also be found in the general product information


Insulation cover

Suitable for appliances with protection class I acc. to IEC 61140

Terminal

Terminals


Terminals according IEC Standard.

Detailed information about terminals can be looked up in the date sheet or in the general product information.

Terminal

Quick connect terminals 6.3 x 0.8 mm

Panel Thickness S

Panel Thickness S



See details in drawing

Snapper

Screw-on mounting: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1 mm to 3 mm

Material: Housing

Thermoplastic, black, UL 94V-0

appliance inlet/-outlet

appliance inlet/-outlet


Connector type according to IEC 60320-1 resp. IEC 60320-2-2, UL498, CSA C22.2 no.42

Details on connectors and their names can be found in the general product information

Appliance Couplers
Mating Connectors
Term explanation
Special Connector Designs

C14 acc. to IEC 60320-1
UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I

Fuseholder

Fuse holder


1.) fuse holder does not include circuit breakers

2.) Details about fuse-links can be found in the catalog under Non-Resettable Fuses

Detailed information on the fuse holder and fuse drawers can be found in the general product information.

Fuse drawer

1 or 2 pole, Shocksafe category PC2 acc. to IEC 60127-6,
for fuse-links 5 x 20 mm

Rated Power Acceptance @ Ta 23 °C

5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per pole

Power Acceptance @ Ta > 23°C

Admissible power acceptance at higher ambient temperature see derating curves

Line Switch

Fuse holder


1.) fuse holder does not include circuit breakers

2.) Details about fuse-links can be found in the catalog under Non-Resettable Fuses

Detailed information on the fuse holder and fuse drawers can be found in the general product information.

Fuse drawer

Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1
Technical Details

Line Filter

Filter Type


Filter classification according leakage current for easy reading:

Standard: < 0.5 mA
Medical: < 0.1 mA

Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8
Technical Details

MTBF

MTBF


The term MTBF is the English acronym Mean Time Between Failure and describes reliability of a component. The operating time of a system can be calculated based on thementioned value of the component. - The higher this value, the more reliable the component.

MTBF

> 2'000'000 h acc. to MIL-HB-217 F

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  
Details about Approvals


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: DD12

Approval Logo Certificates Certification Body Description
Approval marks ENEC 10 VDE Certificate Number: 40001522
Approval marks cURus UL UL File Number: E72928


Product standards

Product standards that are referenced

Organization Design Standard Description
Partners IEC_Certification_Body Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes
Partners IEC_Certification_Body Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference
Partners IEC_Certification_Body Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links
Partners IEC_Certification_Body Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements
Partners UL_Certification_Body Designed according to UL 498 Standard for Attachment Plugs and Receptacles
Partners UL_Certification_Body Designed according to UL 1283 Electromagnetic interference filters
Partners CSA_Certification_Body Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Partners CSA_Certification_Body Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters


Application standards

Application standards where the product can be used

Organization Design Standard Description
Partners IEC_Certification_Body Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment.
Partners IEC_Certification_Body Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
Partners IEC_Certification_Body Designed for applications acc. IEC 60335-1 Safety of electrical appliances for household and similar purposes. Meets the requirements for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-12 and -13.


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE Selbsteklaration SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG EU Directive RoHS 2011/65/EU
Environment_Safety China_RoHS_e_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.
 V_Lock_Logo SCHURTER AG V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset.
Environment_Safety Glow_Wire_Proof SCHURTER AG Meets the requirements of IEC 60335-1 for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-12 and -13.
Environment_Safety Medical.jpg SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1

Preview
 

Picture(s) Selection of product pictures to display a specific variant of the type

Type
 

Type Corresponds to a product series and includes various distinct variants. On the type of descriptive data are summarized, eg in the data sheet

Order Number
 

Order Number Unique part number for placing an order

Configuration key
 

Configuration key The configuration key of a product consists of the composite key values, which describe the different kinds of attribut distinction.

Comment
 
Model Description
 

Model Description Abbreviated description of the CAD model

IGS
 

IGS Also mentioned as IGES ( Initial Graphics Exchange Specification). Common program indipendent interchange format for 3D CAD data.

Step
 

Step Also mentioned as STEP ( Standard for the Exchange of Product Model Data). Common program indipendent interchange format for 3D CAD data standardized according ISO standard.

Parasolid
 

Parasolid Parasolid modeling kernel is a 3D CAD systems. It is developed by a separate business unit within the Unigraphics Solutions (UGS), now Siemens PLM Software.

DXF
 

DXF (Drawing Interchange Format) is a specified by the Autodesk file format for CAD data exchange, and was developed for the 2D-CAD program AutoCAD. A DXF file describes a CAD model as plain text to the ASCII standard.

DD12
DD12.1111.111 DD12.1121.111 DD12.1321.111 DD12.2111.111 DD12.2121.111 DD12.2124.111 DD12.2321.111 DD12.4111.111 DD12.4121.111 DD12.4321.111 DD12.4622.111 DD12.6111.111 DD12.6121.111 DD12.6123.111 DD12.6321.111 DD12.6324.111 DD12.8111.111 DD12.8121.111 DD12.8321.111 DD12.9111.111 DD12.9121.111 DD12.9321.111 DD12.9324.111
DD12.XXXX.XXX CAD-Model shows variation screw-on mounting A, with switch non illuminated, QC terminal 6.3x0.8 mm
DD12
DD12-XXXXX-XXXX-2XXX CAD-Model Shows variation screw-on mounting B, with switch non illuminated, QC terminal 6.3x0.8 mm
DD12
DD12-XXXXX-XXXX-3XXX CAD-Model shows variation snap-in mounting, with switch non illuminated, QC terminal 6.3x0.8 mm

Dimensions [mm]

Screw version A

Screw version B

Snap-in mounting from front side


Diagrams

Standard Version, medical Version M80
non-illuminated
1) Line
2) Load
Medical version M5
non-illuminated
1) Line
2) Load
Standard Version, medical Version M80
with PE-choke
1) Line
2) Load

Medical version M5
with PE-choke
1) Line
2) Load


Derating Curves

1-pole

Admissible power acceptance in Watt
Ambient air temperature Ta °C

2-pole

Admissible power acceptance in Watt per pole
Ambient air temperature Ta °C


Technical Data of Filter-Components

Rated Current [A] Filter-Type Inductance L1/L2 [mH] Inductance L3 [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ]
1 Standard Version 2 x 10 - 100 2.2 1
2 Standard Version 2 x 4 - 100 2.2 1
4 Standard Version 2 x 1.5 - 100 2.2 1
6 Standard Version 2 x 0.8 - 100 2.2 1
8 Standard Version 2 x 0.6 - 100 2.2 1
10 Standard Version 2 x 0.3 - 100 2.2 1
6 Standard Version with Ground Line Choke 2 x 0.8 - 100 2.2 1
10 Standard Version with Ground Line Choke 2 x 0.3 - 100 2.2 1
1 Medical Version (M5) 2 x 10 - 100 - 1
2 Medical Version (M5) 2 x 4 - 100 - 1
4 Medical Version (M5) 2 x 1.5 - 100 - 1
6 Medical Version (M5) 2 x 0.8 - 100 - 1
8 Medical Version (M5) 2 x 0.6 - 100 - 1
10 Medical Version (M5) 2 x 0.3 - 100 - 1
1 Medical Version (M80) 2 x 10 - 100 0.47 1

Attenuation Loss

1 A

2 A

4 A

6 A

8 A

10 A

1 A

2 A

4 A

6 A

8 A

10 A


Short Table of Variants DD12


Rated Current [A] Filter-Type Mounting Order Number

Variant Details


The link on the respective order number refers to a separat tab with specific detailed information .

This assures better readable information of the selected product.
Change to the tab All Products in order to show details of another variant.

This approach offers to use generic alias link to the product details:

www.schurter.xx/art/ [Order Number]

where the following variables are used:
- xx is the country specific domain
- [Order Number]

A=Most Popular

A=Most Popular


Most popular products have the following customer benefits:

- previously ordered by multiple customers
- generally in stock for immediate delivery
- early adoption or mature life cycle

Contact us for availability on other product variants, lead-times vary:

Contact-Form
Availability for all products can be searched real-time. Enter part number and required quantity:

Stock Check SCHURTER

Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application. Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links reffers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.

The
Distributor Stock Check

Stock Check Distributor

...
 
1 Standard Version Screw-on A DD12.1111.111  A  ...
1 Standard Version Snap-in 3-107-465  A  ...
1 Standard Version Screw B 3-109-955 ...
1 Standard Version Screw-on A DD12.1121.111  A  ...
2 Standard Version Screw-on A DD12.2111.111  A  ...
2 Standard Version Snap-in 3-107-466  A  ...
2 Standard Version Screw B 3-109-956 ...
2 Standard Version Screw-on A DD12.2121.111  A  ...
2 Standard Version Screw-on A DD12.2123.111 ...
2 Standard Version Screw-on A DD12.2124.111 ...
4 Standard Version Screw B 3-110-001 ...
4 Standard Version Snap-in 3-110-032 ...
4 Standard Version Screw-on A DD12.4111.111  A  ...
4 Standard Version Snap-in 3-107-467  A  ...
4 Standard Version Screw B 3-109-957 ...
4 Standard Version Screw-on A DD12.4121.111  A  ...
6 Standard Version Snap-in 3-110-010 ...
6 Standard Version Screw B 3-110-031 ...
6 Standard Version Screw-on A DD12.6111.111  A  ...
6 Standard Version Screw B 3-102-857  A  ...
6 Standard Version Snap-in 3-102-861  A  ...
6 Standard Version Screw-on A DD12.6121.111  A  ...
6 Standard Version Screw-on A DD12.6123.111  A  ...
8 Standard Version Screw-on A DD12.8111.111  A  ...
8 Standard Version Snap-in 3-107-468  A  ...
8 Standard Version Screw B 3-109-958 ...
8 Standard Version Screw-on A DD12.8121.111  A  ...
10 Standard Version Screw-on A DD12.9111.111  A  ...
10 Standard Version Screw B 3-105-315  A  ...
10 Standard Version Snap-in 3-107-469  A  ...
10 Standard Version Screw-on A DD12.9121.111  A  ...
6 Standard Version with Ground Line Choke Screw B 3-109-943 ...
10 Standard Version with Ground Line Choke Screw-on A 3-102-855 ...
1 Medical Version (M5) Snap-in 3-107-472  A  ...
1 Medical Version (M5) Screw B 3-109-994 ...
1 Medical Version (M5) Screw-on A DD12.1321.111  A  ...
2 Medical Version (M5) Snap-in 3-107-473  A  ...
2 Medical Version (M5) Screw B 3-109-995 ...
2 Medical Version (M5) Screw-on A DD12.2321.111  A  ...
4 Medical Version (M5) Snap-in 3-107-474  A  ...
4 Medical Version (M5) Screw B 3-109-997 ...
4 Medical Version (M5) Screw-on A DD12.4321.111  A  ...
6 Medical Version (M5) Snap-in 3-107-475  A  ...
6 Medical Version (M5) Screw B 3-109-998 ...
6 Medical Version (M5) Screw-on A DD12.6321.111  A  ...
8 Medical Version (M5) Snap-in 3-107-476  A  ...
8 Medical Version (M5) Screw B 3-109-999 ...
8 Medical Version (M5) Screw-on A DD12.8321.111  A  ...
10 Medical Version (M5) Snap-in 3-107-477  A  ...
10 Medical Version (M5) Screw B 3-110-000 ...
10 Medical Version (M5) Screw-on A DD12.9321.111  A  ...
1 Medical Version (M80) Screw-on A DD12.1621.111 ...

Most Popular.

10 A version only IEC approval.


Alternative: version without line filter (1)

[Swipe to the left and right for more options]

Alternative: version for snap-in mounting (1)

[Swipe to the left and right for more options]

Mating Outlets/Connectors (11)

[Swipe to the left and right for more options]

4787

IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal

4788

IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal

5091

IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal

4782

4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4785

4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4300-06

4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4781

IEC Connector C15 for hot conditions 120°C, Rewireable, Straight

4784

IEC Connector C15 for hot conditions 120°C, Rewireable, Angled

0102-G

IEC Connector C15A, Rewireable, Straight, gold-plated terminals

4771

IEC Connector C15A for very hot conditions 155°C, Rewireable, Straight

4772

IEC Connector C15A, Rewireable, Angled

Mating Outlets/Connectors shuttered (1)

[Swipe to the left and right for more options]

VAC13KS

VAC13KS, Overview, diverse Connector IEC C13, cord end:

Required Accessory (9)

[Swipe to the left and right for more options]

Fusedrawer 2

Fusedrawer für Fuse Links 5x20 mm, with or without Voltage Selector Insert

4301.1401

Fingergrip, 2-pole

4301.1403

Extra-Safe, 2-pole

4301.1405

Fingergrip, 1-pole

4301.1407

Extra-Safe, 1-pole

4301.1409

Fingergrip, 1-pole, spare fuse case

4301.1411

Extra-Safe, 1-pole, spare fuse case

4301.1413

Fingergrip, 2-pole, shorting bar in the neutral side

4301.1415

Extra-Safe, 2-pole, shorting bar in the neutral side

Accessories (5)

[Swipe to the left and right for more options]

Wire Harness

Wire harness for SCHURTER products

Assorted Covers

Rear Cover

Cord retaining kits

Cord retaining strain relief

4700.0001

Flat head, A


ch.schurter.com
en
en
prod //cdn.schurter.com