Series: FMBC LL

New_Logo Free Sample Request

2-stage filter for 3-phase systems with low leakage current

9 Variants



Approvals and Compliances

Description FMBC LL

Description

  • Terminals for three phases and ground

Standards


Approvals

  • Approval Reference Type: FMBC LL
  • VDE Certificate Number: 40040983
  • UL File Number: E72928
Date Category Subcategory Title Download

Rated Current

The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses

Ratings IEC, UL/CSA
General information on the rated current and the rated voltage at EMC products

Rated Voltage
Rated current
The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families


Approvals

7 - 180 A

Rated voltage

The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses

Ratings IEC, UL/CSA
General information on the rated current and the rated voltage at EMC products

Rated Voltage
Rated current
The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families


Approvals

520 VAC, 50/60 Hz

Approval for

Approvals indicate the conformity of the products with the national testing institution requirements by listing of the relevant approval logos.

appr =
Approvals
The link leads you to the search mask where you can query for certificates of the selected products.

Approvals
Detailed information about Approvals will be documented in the general product informations.

Details about Approvals

7 - 180 A @ 50 °C / 520 VAC; 50/60 Hz

Overload Current

1.5 x Ir for 1 minute, per hour

Dielectric Strength

Information abou the maximum permissible voltage, to avoid a voltage breakdown due to insulation damage.


Dielectric Strength

> 2.25 kVDC between L-L
> 2.7 kVDC between L-PE

Test voltage 2 sec

Number of Filter Stages

Quality of a filter

2-stage

Weight

0.75 - 9.4 kg

Material: Housing

Metal 

Sealing Compound

UL 94V-0 

Mounting

Screw-on mounting on chassis 

Terminal

AMP = standardized connector systems and contacts
Abbreviation for "Zero Insertion Force". The so-called ZIF connector takes the flexprint cable without effort, mostly with locking. The advantage of this connector is the gentle treatment of the pin

Screw clamps 

Operating Temperature

-25 °C to 100 °C

Climatic Category

Disposition of components in categories for the assessment of mechanical and electrical properties.

Climatic Category

25/100/21 acc. to IEC 60068-1

Degree of Protection

Disposition of components in categories for the assessment of mechanical and electrical properties.

Climatic Category

IP 20 acc. to IEC 60529

Protection Class

Class I: with ground; Class II: without ground

Detailed information relating to protection class can also be found in the general product information


Insulation cover

Suitable for appliances with protection class I acc. to IEC 61140

MTBF

The term MTBF is the English acronym Mean Time Between Failure and describes reliability of a component. The operating time of a system can be calculated based on thementioned value of the component. - The higher this value, the more reliable the component.

MTBF

> 200'000 h acc. to MIL-HB-217 F


Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  
General Product Information

Preview
 

Picture(s) Selection of product pictures to display a specific variant of the type

Type
 

Type Corresponds to a product series and includes various distinct variants. On the type of descriptive data are summarized, eg in the data sheet

Order Number
 

Order Number Unique part number for placing an order

Configuration key
 

Configuration key The configuration key of a product consists of the composite key values, which describe the different kinds of attribut distinction.

Comment
 
Model Description
 

Model Description Abbreviated description of the CAD model

IGS
 

IGS Also mentioned as IGES ( Initial Graphics Exchange Specification). Common program indipendent interchange format for 3D CAD data.

Step
 

Step Also mentioned as STEP ( Standard for the Exchange of Product Model Data). Common program indipendent interchange format for 3D CAD data standardized according ISO standard.

Parasolid
 

Parasolid Parasolid modeling kernel is a 3D CAD systems. It is developed by a separate business unit within the Unigraphics Solutions (UGS), now Siemens PLM Software.

DXF
 

DXF (Drawing Interchange Format) is a specified by the Autodesk file format for CAD data exchange, and was developed for the 2D-CAD program AutoCAD. A DXF file describes a CAD model as plain text to the ASCII standard.

FMBC LL
FMBC-R91U-0712
FMBC-R91U-xxxx
FMBC LL
FMBC-R91C-1612
FMBC-R91C-xxxx
FMBC LL
FMBC-R91Q-3012
FMBC-R91Q-xxxx
FMBC LL
FMBC-R91R-4212
FMBC-R91R-xxxx
FMBC LL
FMBC-R91S-5512
FMBC-R91S-xxxx
FMBC LL
FMBC-R91F-7512
FMBC-R91F-xxxx
FMBC LL
FMBC-R91G-J012 FMBC-R91G-J312
FMBC-R91G-xxxx
FMBC LL
FMBC-R91V-J812
FMBC-R91V-xxxx

Dimension [mm]

Case 1U

1) Line
2) Load
Case 1C

1) Line
2) Load
Case 1Q

1) Line
2) Load
Case 1R

1) Line
2) Load
Case 1S

1) Line
2) Load
Case 1F

1) Line
2) Load
Case 1G

1) Line
2) Load
Case 1V

1) Line
2) Load

Diagrams

1) Line



Attenuation Loss

7A

16A

30A

42A

55A

75A

100A

130A

180A


Short Table of Variants FMBC LL


Rated Current @ Ta 50°C (40°C) [A] Rated Voltage [VAC] Powerloss @ 25°C, 50Hz [W] Order Number

The link on the respective order number refers to a separat tab with specific detailed information .

This assures better readable information of the selected product.
Change to the tab All Products in order to show details of another variant.

This approach offers to use generic alias link to the product details:

www.schurter.xx/art/ [Order Number]

where the following variables are used:
- xx is the country specific domain
- [Order Number]

A=Most Popular

Most popular products have the following customer benefits:

- previously ordered by multiple customers
- generally in stock for immediate delivery
- early adoption or mature life cycle

Contact us for availability on other product variants, lead-times vary:

Contact-Form
Availability for all products can be searched real-time. Enter part number and required quantity:

Stock Check SCHURTER

Free Sample

Please ask for free sample in order to check if the products meets your requirement for your application. Send your delivery adress and your specific requirements.

Distributor Stock Check

The following links reffers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.

The
Distributor Stock Check

Stock Check Distributor

...
 
7 (7.7) 520 1.5 FMBC-R91U-0712  A  ...
16 (17.5) 520 5.4 FMBC-R91C-1612 ...
30 (32.9) 520 6.6 FMBC-R91Q-3012  A  ...
42 (46) 520 10.7 FMBC-R91R-4212  A  ...
55 (60.2) 520 13.3 FMBC-R91S-5512  A  ...
75 (82.2) 520 19.6 FMBC-R91F-7512  A  ...
100 (109.5) 520 26.3 FMBC-R91G-J012  A  ...
130 (142.4) 520 10 FMBC-R91G-J312  A  ...
180 (197.1) 520 31 FMBC-R91V-J812  A  ...

Most Popular.

1) Nominal leakage current acc. to IEC60950 - 5.2.5. under normal operating conditions. Note: worst case leakage current acc. to IEC60950 - Annex G4 (situation with two interrupted lines) can be much higher.

2) Maximum conductor cross section (wire gauge) to be used; a comparative table for AWG and mm² values can be found in the general product information www.schurter.com/emc_info



en
prod //d1r84oewyu4qpi.cloudfront.net